| Richard Sennett - Marine engines - 1885 - 750 pages
...domes in boilers so fitted, to be stayed from the top of the dome or otherwise stiffened. Stays. — The strength of stays supporting flat surfaces is to be calculated from the weakest part of the stay or fastening, and the strain upon them is not to exceed the following limits,... | |
| Albert Edward Seaton - Marine engineering - 1886 - 514 pages
...domes in boilers so fitted, to be stayed from the top of the dome or otherwise stiffened. Stays. — The strength of stays supporting flat surfaces is...calculated from the smallest part of the stay or fastening; the strain upon them is not to exceed the following limits, viz. : — Iron stays. — For screw stays,... | |
| Albert Edward Seaton - Marine engineering - 1886 - 520 pages
...domes in beilers so fitted, to be stayed from the top of the dome or otherwise stiffened. Stays.—The strength of stays supporting flat surfaces is to be...calculated from the smallest part of the stay or fastening; the strain upon them is not to exceed the following limits, viz.:— Iron stays.—For scre^ stays,... | |
| Walter S. Hutton - Mechanical engineering - 1892 - 558 pages
...Flat-Surfaces. — The strength of stays supporting flatsurfaces is to be calculated from the weakest part of the stay or fastening, and the strain upon...them is not to exceed the following limits, namely : — For Plates For Plates Description of Longitudinal Joint. A Inch thick and under. and above i... | |
| Johann Phillip Edmond Charles Stromeyer - Steam-boilers, Marine - 1893 - 388 pages
...joint, punched holes „ „ „ „ drilled 155 170 170 180 165 170 180 190 180 lilO 190 200 culated from the smallest part of the stay or fastening, and...namely : — Iron Stays. — For stays not exceeding 1 }, in. smallest diameter, and for all stays which are welded, 6,000 Ibs. per sq. in. ; for unwelded... | |
| Johann Phillip Edmond Charles Stromeyer - Steam-boilers, Marine - 1893 - 386 pages
...strength of stays supporting flat surfaces is to be calsf ' t LU'YD'S KFGISTEE BOILER RULES 275 'rulatod from the smallest part of the stay or fastening, and...following limits, namely ; — Iron. Stays. — For st:,ys not exfcedir'g H in. smallest diameter, and for all stays which are welded, o,000 Ibs. per sq.... | |
| Richard Sennett - Marine engines - 1898 - 574 pages
...domes in boilers so fitted, to be stayed from the top of the dome or otherwise stiffened. Stays. — The strength of stays supporting flat surfaces is...namely :— Iron stays. — For stays not exceeding 1£ inches smallest diameter, and for all stays which are welded, 6,000 Ibs. per square inch ; for... | |
| Johann Phillip Edmond Charles Stromeyer - Steam-boilers, Marine - 1901 - 464 pages
...domes in boilers so fitted to be stayed from the top of the dome or otherwise stiffened. Stays. — The strength of stays supporting flat surfaces is...diameter, and for all stays which are welded, 6,000 Ibs. per sq. in. ; for unwelded stays above H in. smallest diameter, 7,500 Ibs. per sq. in. Steel Stays.... | |
| Johann Phillip Edmond Charles Stromeyer - Steam-boilers, Marine - 1901 - 464 pages
...domes in boilers so fitted to be stayed from the top of the dome or otherwise stiffened. Stays. — The strength of stays supporting flat surfaces is...namely : — Iron Stays. — For stays not exceeding 1^ in. smallest diameter, and for all stays which are welded, 6,000 Ibs. per sq. in. ; for unwelded... | |
| Lloyd's Register of Shipping - Ships - 1903 - 252 pages
...flame, the co-efficients should be j of those given above. STAYS. 42. The strength of stays support ing flat surfaces is to be calculated from the smallest...them is not to exceed the following limits, namely : — 43. Iron Stays. — F.or stays not exceeding 1^ inches smallest diameter, and for all stays which... | |
| |