| Rolla Clinton Carpenter, Herman Diederichs - Building materials - 1911 - 1170 pages
...plates specially intended for cold flanging and marked for identification the lower limit shall be 26 tons per square inch. In the case of material for purposes in which tensile strength is not , ; rurnllel.for a length not less than 9" >| 1 .tt .1 = i •* = "-V <j> f « 3P t =^^ 1-5 - ^., .... | |
| Rolla Clinton Carpenter, Herman Diederichs - Building materials - 1913 - 1352 pages
...plates specially intended for cold flanging and marked for identification the lower limit shall be 26 tons per square inch. In the case of material for...important, the tensile test may be dispensed with and the bend-test only be made, if so specified by the builders and approved by the Committee. The elongation,... | |
| Albert Edward Seaton, Henry Morrison Rounthwaite - Marine engineering - 1917 - 772 pages
...for shells sliall be between the limits of 28 and 32 tons per square inch if not otherwise specified. For plates intended for flanging or welding and for combustion chambers and furnaces, also for bars for combustion chamber stays and rivet bars, the tensile breaking strength shall be between... | |
| Johann Phillip Edmond Charles Stromeyer - Boilers, Marine - 1919 - 468 pages
...square inch, but a range of not more than 4 tons per square inch shall be permitted in any one case. For plates intended for flanging or welding, and for...and furnaces, the tensile breaking strength shall be not less than 26 and not more than 30 tons per square inch. The elongation, measured on a Standard... | |
| John of Patrick Gray - Steam-boilers, Marine - 1921 - 160 pages
...show no sign of flaw or crack. The tensile strength of the bars from which the rivets are made should be between the limits of 26 and 30 tons per square inch. Bivding of Joints. — In the best boiler work the rivet holes are drilled after the plates have been... | |
| Albert Edward Seaton, Henry Morrison Rounthwaite - Marine engineering - 1922 - 810 pages
...and for combustion chambers and furnaces, also for bars for combustion chamber stays and rivet bars, the tensile breaking strength shall be between the limits of 26 and 30 tong per square inch. In the case of material for purposes in which tensile strength is not important,... | |
| Lloyd's Register of Shipping - Shipbuilding - 1922 - 348 pages
...on the Standard test piece C. (rf) Rivet Bars. — The tensile breaking strength of rivet bars is to be between the limits of 26 and 30 tons per square inch of section, with an elongation of not less than 25 per cent measured on the Standard test piece В... | |
| 1928 - 378 pages
...plates for combustion chambers and furnaces, bars for combustion chamber stays and rivet bars is to be between the limits of 26 and 30 tons per square inch. Material for purposes in which tensile strength is not important need not be subjected to tensile tests... | |
| Lloyd's Register of Shipping - Shipbuilding - 1920 - 318 pages
...square inch, but a range of not more than 4 tons per square inch shall be permitted in any one case. For plates intended for flanging or welding, and for...between the limits of 26 and 30 tons per square inch. The elongation, measured on a Standard test piece having a gauge length of 8 ins., shall not be less... | |
| Engineering - 1905 - 958 pages
...than 3 per cent, below the abovenamed elongations. The tensile breaking strength of rivet bars are to be between the limits of 26 and 30 tons per square inch of section, with an elongation of not less than 25 per cent, measured on the standard test piece. TEST... | |
| |