| Joseph W. Bramwell - Building materials - 1896 - 398 pages
...180 degrees flat on itself without fracture on outside of bent portion. Soft Steel. — 8. Ultimate strength, 52,000 to 62,000 pounds per square inch. Elastic limit, not less than one- half the ultimate. Elongation, 25 per cent. Bending test, 180 degrees flat on itself without fracture... | |
| Harry Huse Campbell - Steel - 1896 - 432 pages
...shall be of three grades, rivet, soft, and medium. Rivet steel. — Ultimate strength, 48000 to 58000 pounds per square inch. Elastic limit, not less than one-half the ultimate strength. Bending test, 180 degrees, flat on itself, without fracture on outside of bent portion. Soft steel.—... | |
| John Butler Johnson - Building materials - 1897 - 840 pages
...Quench bends, 180 degrees flat on itself, without fracture on outside of bout portion. 9. Ultimate strength, 52,000 to 62,000 pounds per square inch. Elastic limit, not less than one half the ultimate strength. Elongation, 26 per cent. Cold and Quench bends, 180 degrees flat on... | |
| James Nisbit Hazlehurst - Tanks - 1901 - 270 pages
...180 degrees flat on itself, without fracture on outside of bent portion. 10. Soft Steel. — Ultimate strength, 52,000 to 62,000 pounds per square inch....one-half the ultimate strength. Elongation, 25 per cent. Bending test, 1 80 degrees flat on itself, without fracture on outside of bent portion. 11. Medium... | |
| William Frederick Durand - Marine engineering - 1901 - 736 pages
...fracture on outside of bent portion. Flange or Boiler Steel. Ultimate Strength: 52,000 to 62,000 Ib. per square inch. Elastic Limit : Not less than one-half the ultimate strength. Elongation : 25 per cent. Cold and Quench Test : Bends 180 deg. flat on itself without fracture on outside of bent portion. (13)... | |
| James Nisbit Hazlehurst - Tanks - 1901 - 258 pages
...without fracture on outside of bent portion. 11. Medium Steel. — Ultimate strength, 60,000 to 70,000 pounds per square inch. Elastic limit, not less than one-half the ultimate strength. Elongation, 22 per cent. Bending test, 180 degrees to a diameter equal to thickness of piece tested, without fracture... | |
| Cambria Steel Co - Building - 1901 - 448 pages
...without fracture on outside of bent portion. FIRE B0X STEEL. 9. intimate strength, 52 000 to 62 000 pounds per square inch. Elastic limit, not less than one-half the ultimate strength. Elongation, 26 per cent. Cold and quench bends, 180 degrees flat on itself, without fracture on outside of bent... | |
| William Frederick Durand - Marine engineering - 1901 - 738 pages
...cent. PHYSICAL PROPERTIES. Extra Soft and Boiler Rivet Steel. Ultimate Strength: 45,000 to 55,000 Ib. per square inch. Elastic Limit : Not less than one-half the ultimate strength. Elongation : 28 per cent. Cold and Quench Test : Bends 180 deg. flat on itself without fracture on outside of... | |
| John Butler Johnson - Engineering - 1902 - 600 pages
...degrees flat on itself, without fracture on outside of bent portion. 104. Soft Steel shall have: Ultimate strength, 52,000 to 62,000 pounds per square inch....one-half the ultimate strength. Elongation, 25 per cent. Bending test, 180 degrees flat on itself, without fracture on outside of bent portion. 105. Medium... | |
| National Tube Co - Engineering - 1902 - 362 pages
...flat on itself, without fracture on outside of bent portion. Flange or Boiler Steel (10). Ultimate strength, 52,000 to 62,000 pounds per square inch....one-half the ultimate strength. Elongation, 25 per cent. Cold and Quench bends, 180 degrees flat on itself, without fracture on outside of bent portion. Boiler... | |
| |