| American Society of Naval Engineers - Marine engineering - 1907 - 1334 pages
...for wrought-iron or steel pipes, for salt water, to be of cast-iron or steel, galvanized. "Pipes will be so led and flanges so placed that they may be readily taken down for renewal or repairs, and so that joints will be kept readily accessible. "All external fittings... | |
| Stephen Christie - Steam-boilers - 1908 - 272 pages
...construction was commenced after June 30, 1905, no bend will be allowed in copper pipe of which the radius is less than one and one-half times the diameter of the pipe and such pipe must be so led and flanges so placed that they may be readily taken down if required. Such pipes must... | |
| Henry Charles Dinger - Marine engineering - 1908 - 338 pages
...for wrought-iron or steel pipes, for salt water, to be of cast-iron or steel, galvanized. "Pipes will be so led and flanges so placed that they may be readily taken down for renewal or repairs, and so that joints will be kept readily accessible. "All external fittings... | |
| Bridgeport Brass Company (Bridgeport, Conn.) - Tubes - 1913 - 112 pages
...construction was commenced after June 30, 1905, no bend will be allowed in copper pipe of which the radius is less than one and one-half times the diameter of the pipe, and such pipe must be so led and flanges so placed that they may be readily taken down if required. Such pipes must... | |
| United States - 1916 - 696 pages
...construction was commenced after June 30, 1905, no bend shall be allowed in copper pipe of which the radius is less than one and one-half times the diameter...that they may be readily taken down if required. Such pines shall be protected by iron casings when run through coal bunkers, and shall be Any pipe used... | |
| William Frederick Durand - Marine engineering - 1917 - 1012 pages
...radius not to exceed the thickness of the pipe. No bend shall be allowed in copper pipe of which the radius is less than one and one-half times the diameter...placed that they may be readily taken down if required. The thickness of material, according to the working pressure, shall be determined by the following... | |
| William Frederick Durand, Charles Wilson Dyson - Marine engineering - 1917 - 1016 pages
...PIPES not to exceed the thickness of the pipe. No bend shall be allowed in copper pipe of which the radius is less than one and one-half times the diameter...placed that they may be readily taken down if required. The thickness of material, according to the working pressure, shall be determined by the following... | |
| William Frederick Durand - Marine engineering - 1917 - 1014 pages
...PIPES not to exceed the thickness of the pipe. Xo bend shall be allowed in copper pipe of which the radius is less than one and one-half times the diameter...and flanges so placed that they may be readily taken clown if required. The thickness of material, according to the working pressure, shall be determined... | |
| United States. Steamboat Inspection Service - Coastwise shipping - 1918 - 220 pages
...shall be allowed in copper pipe of ich the radius is less than one and one-half times the diameter of : pipe, and such pipe shall be so led and flanges so placed that they y be readily taken down if required. Such pipes shall be proted by iron casings when run through coal... | |
| |