| Emory Edwards - Steam engineering - 1888 - 540 pages
...cylindrical shell, and divide by the radins or half diameter — also expressed in inches — and the sum will be the pressure allowable per square inch of surface for single riveting, to which add twenty per centum for double-riveting. 4. The hydrostatic pressure applied must be in proportion of... | |
| Robert Wilson - Steam-boilers - 1889 - 490 pages
...cylindrical shell, and divide by the radius or half diameter— -expressed in inches, —and the sum will be the pressure allowable per square inch of surface for single riveting, to which add 20 per centum for double riveting." The hydrostatic pressure applied under the above rule must be in the proportion... | |
| Robert Wilson - Steam-boilers - 1889 - 492 pages
...cylindrical shell, and divide by the radius or half diameter — expressed in inches, — and the sum will be the pressure allowable per square inch of surface for single riveting, to which add 20 per centum for double riveting." The hydrostatic pressure applied under the above rule must be in the proportion... | |
| Emory Edwards - Marine engineering - 1891 - 554 pages
...cylindrical shell, and divide by the radius or half diameter — also expressed in inches — and the sum will be the pressure allowable per square inch of surface for single riveting, to which add twenty per centum for double-riveting. 4. The hydrostatic pressure applied must be in proportion of... | |
| United States - Ships - 1895 - 360 pages
...cylindrical shell, and divide by the radius or half diameter—also expressed in inches— and the sum will be the pressure allowable per square inch of...surface for single riveting, to which add 20 per cent for double riveting, when all the holes have been ''fairly drilled" and no part of such hole has been... | |
| Power - Steam engineering - 1897 - 252 pages
...cylindrical shell, and divide by the radius or half diameter, also expressed in inches, and the sum will be the pressure allowable per square inch of surface for single riveting, to which add twenty per centum for double riveting." Q. 215 — Is not the factor of safety in this rule 6? A. —... | |
| William Miller Barr - Furnaces - 1898 - 430 pages
...cylindrical shell and divide by the radius, or half-diameter, — also expressed in inches, — and the sum will be the pressure allowable per square inch of...surface for single riveting, to which add 20 per cent. for double riveting, when all the rivetholes in the shell of such boiler have been ' fairly drilled'... | |
| Nehemiah Hawkins - Steam-boilers - 1900 - 358 pages
...of the thinnest plate in the same cylindrical shell, and divide by the radius or half diameter — also expressed in inches — and the result will be...inch of surface for single- riveting, to which add twenty per centum for double riveting. The hydrostatic pressure applied, under this table and rule,... | |
| William Frederick Durand - Marine engineering - 1901 - 738 pages
...shell, and divide, by the radius or half diameter — also expressed in inches — and the quotient will be the pressure allowable per square inch of...surface for single riveting, to which add 20 per cent for double riveting. when all the rivet holes in the shell of such boiler have been "fairly drilled"... | |
| William Frederick Durand - Marine engineering - 1901 - 736 pages
...shell, and divide by the radius or half diameter — also expressed in inches — and the quotient will be the pressure allowable per square inch of surface for single riveting, to which add 2O per cent for double riveting, when all the rivet holes in the shell of such boiler have been "fairly... | |
| |