| Frank Eugene Kidder - Building - 1909 - 1000 pages
...shall be directed against the under side of the floor, discharged through a one-andone-eighth-inch nozzle, under sixty pounds nozzle pressure, for ten...unless the following conditions are met : No fire nor smoke shall pass through the floor during the fire test ; the floor must safely sustain the loads... | |
| Frank Eugene Kidder - Building - 1909 - 998 pages
...shall be directed against the under side of the floor, discharged through a one-andone-eighth-inch nozzle, under sixty pounds nozzle pressure, for ten...successful unless the following conditions are met : Xo fire nor smoke shall pass through the floor during the fire test ; the floor must safely sustain... | |
| American Society for Testing Materials - Building materials - 1910 - 326 pages
...hose stream being played backward and forward over the entire surface of the partition under test. The test shall not be regarded as successful unless...are met : No fire or smoke shall pass through the partition during the fire test; the partition must safely sustain the pressure of the hose stream;... | |
| Building materials - 1913 - 420 pages
...the nozzle being held not more than 3 ft. from the firing door during the application of the water. After the floor has sufficiently cooled the load on the same shall be increased to 600 Ibs. per sq. ft., uniformly distributed. The test shall not be regarded as successful unless the... | |
| New York (State). Dept. of Labor - Arbitration, Industrial - 1915 - 668 pages
...must be accurately determined at the nozzle by means of nozzle stream Pitot tube with pressure gauge. After the floor has sufficiently cooled the load on the same shall be increased to C0O pounds per square foot, uniformly distributed in segregated piles without arching. Deflection readings... | |
| New York (State). - 1915 - 300 pages
...obtained must be accurately determined at the nozzle by means of stream Pitot tube with pressure gauge. After the floor has sufficiently cooled the load on the same shall creased to 600 pounds per square foot, uniformly distributed in seg piles without arching. Deflection... | |
| New York (State). Industrial Commission - Arbitration, Industrial - 1916 - 824 pages
...must be accurately determined at the nozzle by means of nozzle stream Pitot tube with pressure gauge. After the floor has sufficiently cooled the load on the same shall be increased to 600 pounds per square foot, uniformly distributed in segregated piles without arching. Deflection readings... | |
| Materials - 1916 - 806 pages
...the nozzle being held not more than 3 ft. from the firing door during the application of the water. After the floor has sufficiently cooled the load on the same shall be increased to 600 Ib. per sq. ft., uniformly distributed. The test shall not be regarded as successful unless the... | |
| American Society of Agricultural Engineers - Agricultural engineering - 1917 - 790 pages
...shall be increased to 200 pounds per square ft, uniformly distributed. The test shall not be considered as successful unless the following conditions are met, no fire or smoke shall pass through anv of the walls of the test structure during the test. WG KAISKR". At the present time there is a... | |
| Materials - 1918 - 992 pages
...stresses equal to the maximum safe working stress allowed in the material of the member. TABLE I. 14. The test shall not be regarded as successful unless the following conditions are met: (a) The floor or roof shall have sustained safely the full rated safe working load during the fire... | |
| |