" The test shall not be regarded as successful unless the following conditions are met: No fire or smoke shall pass through the floor during the fire test; the floor must safely sustain the loads prescribed ; the permanent deflection, must not exceed one-eighth... "
The Architect's and Builder's Pocket-book: A Handbook for Architects ... - Page 743
by Frank Eugene Kidder - 1908 - 1661 pages
Full view - About this book

Building Construction and Superintendence, Part 1

Frank Eugene Kidder - Building - 1909 - 1000 pages
...shall be directed against the under side of the floor, discharged through a one-andone-eighth-inch nozzle, under sixty pounds nozzle pressure, for ten...unless the following conditions are met : No fire nor smoke shall pass through the floor during the fire test ; the floor must safely sustain the loads...
Full view - About this book

Building Construction and Superintendence, Part 1

Frank Eugene Kidder - Building - 1909 - 998 pages
...shall be directed against the under side of the floor, discharged through a one-andone-eighth-inch nozzle, under sixty pounds nozzle pressure, for ten...successful unless the following conditions are met : Xo fire nor smoke shall pass through the floor during the fire test ; the floor must safely sustain...
Full view - About this book

Year-book

American Society for Testing Materials - Building materials - 1910 - 326 pages
...hose stream being played backward and forward over the entire surface of the partition under test. The test shall not be regarded as successful unless...are met : No fire or smoke shall pass through the partition during the fire test; the partition must safely sustain the pressure of the hose stream;...
Full view - About this book

Year-book

Building materials - 1913 - 420 pages
...the nozzle being held not more than 3 ft. from the firing door during the application of the water. After the floor has sufficiently cooled the load on the same shall be increased to 600 Ibs. per sq. ft., uniformly distributed. The test shall not be regarded as successful unless the...
Full view - About this book

Annual Report of the Commissioner of Labor, Issue 14

New York (State). Dept. of Labor - Arbitration, Industrial - 1915 - 668 pages
...must be accurately determined at the nozzle by means of nozzle stream Pitot tube with pressure gauge. After the floor has sufficiently cooled the load on the same shall be increased to C0O pounds per square foot, uniformly distributed in segregated piles without arching. Deflection readings...
Full view - About this book

The Labor law, the Industrial code, the Workmen's compensation law

New York (State). - 1915 - 300 pages
...obtained must be accurately determined at the nozzle by means of stream Pitot tube with pressure gauge. After the floor has sufficiently cooled the load on the same shall creased to 600 pounds per square foot, uniformly distributed in seg piles without arching. Deflection...
Full view - About this book

Annual Report of the Industrial Commission

New York (State). Industrial Commission - Arbitration, Industrial - 1916 - 824 pages
...must be accurately determined at the nozzle by means of nozzle stream Pitot tube with pressure gauge. After the floor has sufficiently cooled the load on the same shall be increased to 600 pounds per square foot, uniformly distributed in segregated piles without arching. Deflection readings...
Full view - About this book

A.S.T.M. Standards

Materials - 1916 - 806 pages
...the nozzle being held not more than 3 ft. from the firing door during the application of the water. After the floor has sufficiently cooled the load on the same shall be increased to 600 Ib. per sq. ft., uniformly distributed. The test shall not be regarded as successful unless the...
Full view - About this book

Transactions, Volumes 10-12

American Society of Agricultural Engineers - Agricultural engineering - 1917 - 790 pages
...shall be increased to 200 pounds per square ft, uniformly distributed. The test shall not be considered as successful unless the following conditions are met, no fire or smoke shall pass through anv of the walls of the test structure during the test. WG KAISKR". At the present time there is a...
Full view - About this book

A.S.T.M. Standards

Materials - 1918 - 992 pages
...stresses equal to the maximum safe working stress allowed in the material of the member. TABLE I. 14. The test shall not be regarded as successful unless the following conditions are met: (a) The floor or roof shall have sustained safely the full rated safe working load during the fire...
Full view - About this book